Nelson Rules (Western Electric)

Pattern rules for detecting special causes on control charts — 8 rules that go beyond the plain ±3σ test.

Also known as: Nelson rules, Western Electric rules, WECO rules, runs rules

The Nelson rules (Nelson, 1984) extend the classic Western Electric rules (1956) and codify typical patterns that indicate a special cause. They use zones A, B, C between the centre line and control limits (each 1σ wide).

  • Rule 1 — 1 point outside ±3σ (out-of-limit)
  • Rule 2 — 9 points in a row on the same side of the centre line (level shift)
  • Rule 3 — 6 points in a row rising or falling (trend)
  • Rule 4 — 14 points alternating (systematic zig-zag)
  • Rule 5 — 2 of 3 points in zone A (>2σ, same side)
  • Rule 6 — 4 of 5 points in zone B or beyond (>1σ, same side)
  • Rule 7 — 15 points in a row within zone C (variance too small → mixing / wrong limits)
  • Rule 8 — 8 points in a row outside zone C (no point near the centre line)

On the MR, R and S chart only rules 1–4 are checked (as in Minitab); the zone rules 5–8 apply to the individuals or X̄ chart only.

See also

Used in

In the Algorithm Lab

Sources

  • Nelson, L. S. — Technical Aids: The Shewhart Control Chart — Tests for Special Causes, Journal of Quality Technology, 16(4), 1984
  • Western Electric Company — Statistical Quality Control Handbook, 1956