Nelson Rules (Western Electric)
Pattern rules for detecting special causes on control charts — 8 rules that go beyond the plain ±3σ test.
Also known as: Nelson rules, Western Electric rules, WECO rules, runs rules
The Nelson rules (Nelson, 1984) extend the classic Western Electric rules (1956) and codify typical patterns that indicate a special cause. They use zones A, B, C between the centre line and control limits (each 1σ wide).
- Rule 1 — 1 point outside ±3σ (out-of-limit)
- Rule 2 — 9 points in a row on the same side of the centre line (level shift)
- Rule 3 — 6 points in a row rising or falling (trend)
- Rule 4 — 14 points alternating (systematic zig-zag)
- Rule 5 — 2 of 3 points in zone A (>2σ, same side)
- Rule 6 — 4 of 5 points in zone B or beyond (>1σ, same side)
- Rule 7 — 15 points in a row within zone C (variance too small → mixing / wrong limits)
- Rule 8 — 8 points in a row outside zone C (no point near the centre line)
On the MR, R and S chart only rules 1–4 are checked (as in Minitab); the zone rules 5–8 apply to the individuals or X̄ chart only.
See also
- Control Chart
- Control Limit (UCL / LCL)
- Special Cause
- Centre Line (CL)
- Nelson Rule 1: Point beyond 3σ
- Nelson Rule 2: 9 points on one side
- Nelson Rule 3: 6 points rising or falling
- Nelson Rule 4: 14 points alternating
- Nelson Rule 5: 2 of 3 points beyond 2σ
- Nelson Rule 6: 4 of 5 points beyond 1σ
- Nelson Rule 7: 15 points in zone C
- Nelson Rule 8: 8 points outside zone C
Used in
In the Algorithm Lab
Sources
- Nelson, L. S. — Technical Aids: The Shewhart Control Chart — Tests for Special Causes, Journal of Quality Technology, 16(4), 1984
- Western Electric Company — Statistical Quality Control Handbook, 1956
- Montgomery, D. C. — Introduction to Statistical Quality Control, 8th Edition, Chapter 5